1. Data Collection

  1. Before recording data, ensure the software has loaded the configuration file. This can be done through the "File - Load Calibration File" option, or a new configuration file can be generated through calibration.

  2. Attach reflective markers to the captured object and place it in the field.

  3. Enter the name of the data file to be collected in the "File Box" below the software interface, avoiding Chinese characters or special symbols. After confirming, click Enter (10.1.1).

  4. After entering the file name for recording data, click the red recording button below to start recording, and then click the button to stop recording. A pop-up window will prompt that the data has been recorded (10.1.2).

  5. After recording a set of data, the number on the right side of the "File" input box will change to 2, indicating that it is about to record the second set of data with that file name. With the file name unchanged, the number will gradually increase after each set of data is recorded (10.1.3, 10.1.4);\

  6. If there are problems recording the second set of data, or for other reasons, you want to re-record that set of data, change the number to 2. Then, click the "Overwrite" button on the left and click the recording button to re-record (10.1.5). You can also do the same for other sets of data.

  7. When recording, XINGYING will check to see if there are calibration files in the current recording directory. If there are no calibration files in the current recording directory, the last loaded calibration file will be automatically copied to the current recording directory.