KUNWEI

  1. Digital force plates support domestic Kunwei and Aili force plates. If you are using Aili force plates, please contact our engineering team for assistance. The following configuration instructions are only for Kunwei force plates.

  2. Connect the Kunwei force plate to power. Due to the default IP subnet of the Kunwei force plate being different from that of the motion capture system, you need to change the IP of the Kunwei force plate to the 10.1.1.X subnet.

  3. The method for setting the IP of the Kunwei force plate is to contact Kunwei manufacturer directly. If the user chooses not to use the 10.1.1.X IP address, then please use a dual-network card host and ensure that the IP of the Kunwei force plate is correctly configured.

  4. After configuring the force plate IP, you can open the command prompt and enter the configured IP address to see if it can be pinged. Once communication is successful, you can proceed to configure the force plate parameters in the motion capture software.

    To configure the force plate in XINGYING:

    1. Open XINGYING and click on the force plate menu.

    2. Select 'Force Plate Parameter Settings.'

    3. In the force plate parameter settings window, under 'Other Configurations,' check 'Digital Force Plate (Network).'

    4. Click the '+' button to add a Kunwei force plate.

    5. Select the added force plate and configure its parameters on the right side.

  5. In the 'IP Address' input box, enter the IP address you have set for your force plate. For example, if the IP address of your Kunwei force plate is 10.1.1.194, then enter 10.1.1.194 in the IP address field. In the 'Port' field, enter the corresponding port number. For example, if the IP address of your Kunwei force plate is 10.1.1.19X, then its port number is 888X.

  6. When you have multiple Kunwei force plates, please repeat steps 1-5 mentioned above for each force plate. Also, ensure that you correctly set the center of the force plate according to its actual placement.

  7. After completing all parameter configurations , please click the 'Apply' button to save your changes.